1. Purpose
Gathers exactly the sprinklers (SK) before running batch commands like ASKPipe1, ASKPipe2, or Set DN by SK. Select a messy mix of pipes, lights, ceilings — this command shrinks the selection down to SKs only, including SKs inside groups.
2. Quick video (≤ 2 minutes)
[Video in production — follow the steps below for now.]
3. Steps
- Select the area containing sprinklers (select generously, other objects may be included). [image 01: mixed-object selection]
- Run the FilterSK command (the SK filter — the current build has no dedicated ribbon button for it).
- The selection shrinks to sprinklers only, duplicates removed automatically. [image 02: post-filter selection with SKs only]
- Continue with ASKPipe1, ASKPipe2, or Set DN by SK on this clean selection.
4. Real-world example
A floor plan has 60 sprinklers scattered inside typical-room groups, mixed with cable trays and ducts. Select the whole floor, then filter SK — the selection holds exactly the 60 SKs, ready for a batch ASKPipe1 run with no stray objects.
5. Common errors
| Symptom | Fix |
|---|---|
| "Vui lòng chọn Elements." | Select at least 1 object before running the command |
| The selection is empty after filtering | The original selection had no sprinklers — check again |
| Grouped SKs missing from the selection | Rerun (the tool unpacks group members; verify the group really holds SKs) |