1. Purpose

Bends one pipe/duct run that hits an obstacle (beam, another pipe) into an over/under detour, typing the vertical offset (mm) and fitting angle in a dialog. No deleting and redrawing the whole run.

2. Quick video (≤ 2 minutes)

[Video in production — follow the steps below for now.]

3. Steps

  1. Open a view showing where the run hits the obstacle. [image 01: pipe hitting a beam]
  2. Click Reroute inside Reroute Tools in the VP_MEP tab, Common panel.
  3. Pick the run and the first break point when asked.
  4. Pick the second break point when asked — the segment between the 2 points is what bends aside. [image 02: two break points bracketing the obstacle]
  5. In the dialog, type the Vertical Offset (mm) and pick the Fitting Angle (degrees), then OK — the tool builds the detour over the obstacle. [image 03: offset and angle dialog]

4. Real-world example

A DN50 water pipe hits a 300 mm corridor beam. Run the command, pick the pipe, place 2 points around the beam, type 350 mm offset, 45 degrees — the run bends over the beam and flows again in one click.

5. Common errors

SymptomFix
Break points too close, no detour buildsSpread the 2 points farther apart for room to bend both ends
Offset too small, the run still hits the obstacleType an offset bigger than the obstacle and rerun
The fitting angle isn't listedPick the nearest angle in the dialog (list follows the project's fitting types)